L4064B1451
- Turns Fan On/Off According to Plenum Temperature
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064A, B, E.
- 11-1/2" Insertion
- Rigid Bracket Mounting
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
- Insertion Tube Adapter - 5/8", 3/4" & 1"
- Two Snap-On Strain Reliefs
L4064B1469
- Turns Fan On/Off According to Plenum Temperature
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064A, B, E.
- 5" Insertion
- Rigid Bracket Mounting
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
- Insertion Tube Adapter - 5/8", 3/4" & 1"
- Two Snap-On Strain Reliefs
L4064B2210
- Turns Fan On/Off According to Plenum Temperature
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064A, B, E.
- 11-1/2" Insertion
- Surface Mounting
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
L4064B2228
- Turns Fan On/Off According to Plenum Temperature
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064A, B, E.
- 5" Insertion
- Surface Mounting
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
L4064B2236
- Turns Fan On/Off According to Plenum Temperature
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064A, B, E.
- 8" Insertion
- Surface Mounting
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
L4064W1080
- Bi-Metal Heater Switch Turns Fan On Approx. 20 to 90 Seconds
After a Call for Heat at a Cold Start.
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064T, Y.
- 5" Insertion
- Surface or Rigid Mounting Bracket Mount
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
L4064W1098
- Bi-Metal Heater Switch Turns Fan On Approx. 20 to 90 Seconds
After a Call for Heat at a Cold Start.
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064T, Y.
- 8" Insertion
- Surface or Rigid Mounting Bracket Mount
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
L4064W1106
- Bi-Metal Heater Switch Turns Fan On Approx. 20 to 90 Seconds
After a Call for Heat at a Cold Start.
- Helical Bi-Metal Sensing Element
- High Limit Factory Set as 200F
- Replacement for L4064T, Y.
- 11-1/2" Insertion
- Surface or Rigid Mounting Bracket Mount
- Two 5" Lead Wires with 1/4" Male Flag Quick-Connections
- Four Add-On Screw Terminals, Two Jumpers for Line Voltage
Fan & Limit Interconnection
Back to
Honeywell Control
Index Page