T87F1826
- 60 to 90 Degrees
- Field Adjustable Temperature Range Stops
- Includes Locking Cover and Locking Dial
- Gold
- Terminals R & W
T87F1859
- 40 to 90 Degrees
- Replaces Heating, Cooling and Heating-Cooling models (Use
Q539 Sub-Base for Heating-Cooling)
- Includes 6 Inch Cover Ring and 137421A 3-Terminal Wall Plate
- Gold
- Terminals R, W & Y
T87F1867
- 50 to 90 Degrees
- Positive OFF
- Includes 6 Inch Cover Ring and 137421A 3-Terminal Wall Plate
- Gold
- Terminals R, W & Y
T87F2360
- 40 to 90 Degrees
- Fixed Temperature Range Stops at 45F and 75F
- Includes 104456B 2-Terminal Heating Only Wall Plate
- Gold
- Terminals R & W
T87F2378
- 50 to 100 Degrees
- For Use In W884 Comfort Control Center
- Gold
- Terminals R & W
T87F2782
- 35 to 65 Degrees
- Field Adjustable Temperature Range Stops
- Includes Locking Cover and Locking Dial, Allenhead Screws
and Wrench for Locking Cover
- 137421A 3-Terminal Wall Plate
- Gold
- Terminals R, W & Y
T87F2790
- 45 to 75 Degrees
- Field Adjustable Temperature Range Stops Set At 68F
- Includes Locking Cover and Locking Dial
- Gold
- Terminals R, W & Y
T87F2816
- 38 to 72 Degrees
- DoD Heating Only Model
- Includes Wallplate, Locking Cover and Locking Dial. No Thermometer.
- Gold
- Terminals R & W
T87F2824
- 78 to 112 Degrees
- DoD Cooling Only Model
- Includes Wallplate, Locking Cover and Locking Dial. No Thermometer.
- Gold
- Terminals R & Y
T87F2873
- 40 to 90 Degrees
- Includes Concealed 104456B 2-Terminal Heating Only Wallplate
- Gold
- Terminals R & W
T87F3467
- 40 to 90 Degrees
- Enlarged Scale and Raised Designations - Easy To See Model
- Includes 137421A 3-Terminal for Heating-Cooling Systems
- Gold
- Terminals R, W & Y
T87F3855
- 40 to 90 Degrees
- Includes Concealed 104456B 2-Terminal Heating Only Wallplate
- Premier White
- Terminals R & W
T87F4002
- 40 to 90 Degrees
- Use With Q539A4000 for Heating-Cooling
- Includes 104456B 2-Terminal Wall Plate
- Designer Beige
- Terminals R & W
T87F4010
- 40 to 90 Degrees
- Includes 6 Inch Cover Ring and 137421A 3-Terminal Wall Plate
- Designer Beige
- No Terminals - Use Q539A
T87F5199
- 40 to 90 Degrees
- Enlarged Scale and Raised Designations - Easy To See Model
- Includes 137421A 3-Terminal for Heating-Cooling Systems
- Premier White
- Terminals R, W & Y
Q539A1014
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, B, G, O
- Gold
- For Conventional Single Transformer Heating-Cooling Systems
Q539A1022
- COOL-OFF-RESET-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, B, G, O
- Gold
- With RESET Switch on System Switch
Q539A1121
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, B(4), G, O
- Gold
- Designed for use with Gas AirConditioners
Q539A1147
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals Rc, Rh, W, Y, G
- Gold
- Independent Heat and Cool Circuits
Q539A1162
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, B, G, O
- Gold
- Use With W884 Comfort Center
Q539A1196
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, G
- Gold
- Isolated Fan Circuit
Q539A1451
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, G, Rh
- Premier White
- Independent Heat-Cool Circuits
Q539A1469
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, B, G, O
- Premier White
- For Conventional Single Transformer Heating-Cooling Systems
Q539A4000
- COOL-HEAT-OFF System Switch
- ON-AUTO Fan Switch
- Terminals Rc, W, Y, B, G, Rh
- Designer Beige
- Independent Heat-Cool Circuits
Q539A4026
- COOL-OFF-HEAT System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, B, G, O
- Designer Beige
- For Conventional Single Transformer Heating-Cooling Systems
Q539B1005
- COOL-OFF-HEAT System Switch
- NO Fan Switch
- Terminals R, W, Y, O, B
- Gold
- Internal System Fan Control
Q539C1020
- COOL-OFF System Switch
- ON-AUTO Fan Switch
- Terminals R, Y, G, O
- Gold
- For Cooling Only Applications
Q539G1000
- HEAT-OFF System Switch
- ON-AUTO Fan Switch
- Terminals R, W, B, G, 1
- Gold
- For Summer Fan Operation - Without Fan Control in Heating
Only Systems
Q539H1009
- NO System Switch
- ON-AUTO Fan Switch
- Terminals R, W, Y, G, Z
- Gold
- With Extra Terminal for Low Volt Fan Control in AUTO Position
Q539J1006
- COOL-OFF-HEAT System Switch
- AUTO-ON Fan Switch
- Terminals R, W, Y, B, G, O, P
- Gold
- Automatic Fan on Both Heating and Cooling
- For Heat Pump with Electric Aux. Heat
Q539J1022
- COOL-OFF-HEAT System Switch
- AUTO-ON Fan Switch
- Terminals R, W, Y, B, G, O, P
- Gold
- Automatic Fan on Both Heating and Cooling for Heat Pump with
Electric Aux. Heat
- For Use in W884 Comfort Center
Q539J1154
- COOL-OFF-HEAT System Switch
- AUTO-ON Fan Switch
- Terminals R, W, Y, B, G, O, P
- Premier White
- Automatic Fan on Both Heating and Cooling for Heat Pump with
Electric Aux. Heat
Back to
Honeywell Control Index Page