PILOT RELITE CONTROL

Pilot Relite Control: 5059 & 5059A

Ignition control generates spark pulses to ignite pilot gas. The relite control generates sparks until a pilot flame is sensed between the electrode and ground., The relite control detects a flame through "Flame Conduction" (ability of a flame to conduct a current) when flame current is sensed between the electrode and pilot burner ground. The relite control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant the flame goes out.

Lockout Timer: 5022

Required on systems for LP gas. The control consists of a warp-switch timer circuit that is wired to the flame sensor. The function of the lockout timer is to de-energize the gas valve if a pilot is not established. The lockout timer circuit is de-energized once the flame sensor transfers to the "Hot" position and energizes the main valve.

Combination Relite Control and Lockout Timer: 50A22

Combines in one enclosure the functions of one 5059 and one 5022 controls.

Model 5058 Electronic Ignitor

This control is a solid state ignition device for use in the ignition of gas operated heaters, furnaces or appliances. 24, 120 and 240VAC models are available.

Ignition Electrode Assemblies

Pilot Relite, Electronic Ignitor and Lockout Timer Cross Reference

Safety Switch and Relay

Special Purpose Solenoid Valves for Automatic Pilot Re-Ignition Systems

Electric Ignition for pilots with Mercury Flame Sensors

Permits lighting of pilot electrically by use of remote switch or pushbutton. Eliminates inconvenience and hazards of hand lighting.